Fire Safety Inspection Checklist
This comprehensive fire safety inspection checklist is designed to streamline routine fire safety assessments and verify that building owners and occupants are adhering to established fire protection procedures and protocols. It serves as a proactive tool to strengthen fire safety awareness, identify potential fire hazards, and ensure timely corrective actions. Capture photographic evidence of equipment defects that could contribute to fires or explosions, thoroughly document all findings, and leverage analytical insights to track recurring issues, evaluate overall facility safety, and demonstrate compliance with fire safety regulations.
Use this template with flowdit
- Customize this template or build your own
- Complete inspections using the mobile app
- Get reports and analyze your data
Start inspecting smarter — free for one user.
How to Use This Checklist
- Walk the building along the route an occupant would take during an evacuation, so that escape route conditions are seen as they would be in a real emergency.
- Test smoke protection doors by opening and closing them, checking that they self-close, that hinges are sound, and that glazing is not compromised.
- Survey escape routes for obstructions such as rubbish, discarded furniture, unauthorised cabinets or shelving, and unauthorised wall penetrations.
- Check that doors onto escape routes open from the inside without a key, and that the main roof access door is not locked from the inside.
- Confirm emergency lighting and exit signs are illuminated and legible, and measure the minimum clear width of the primary escape route.
- Inspect every fire extinguisher, manual alarm call point, hydrant, and hose reel for damage, obstruction, and maintenance status.
- Check signs for fire department connections, sprinkler connections, hose reel cabinets, and hose reel storage for legibility and completeness.
- Verify that fire department inlet connections are not obstructed by swing gates, furniture, or other objects, and that fire department elevator signage is present and legible.
- Inspect sprinkler heads for obstructions from shelving, merchandise, or fixed structures, and measure the clearance below the nearest sprinkler head to confirm it is at least 500 mm.
- Ask whether fire protection systems and the building's ventilation system are maintained and inspected annually by registered service companies or contractors.
- Examine electrical wiring and cables for damage, fraying, or improper installation, and record the specific location of any hazards found.
- Capture photographic evidence of equipment defects that could contribute to fires or explosions.
- Assign an overall electrical safety condition rating and an overall fire safety compliance rating on a 0 to 10 scale, and set a priority level for the issues identified.
- Write a summary of key findings, identified risks, and recommended corrective actions, then sign and close out the inspection.
Start inspecting smarter — free for one user.
What a fire safety inspection covers
This checklist is built around four operational areas. Smoke protection door management covers the condition and operation of doors that are meant to hold back smoke, including missing or damaged doors, faulty hinges, compromised glazing, doors propped open with wedges, and doors that fail to self-close. Escape route management covers obstructions, locking arrangements, unauthorised penetrations and structures, emergency lighting, exit signs, and the measured clear width of the primary route. Fire equipment maintenance covers extinguishers, manual alarm call points, hydrants, hose reels, signage for fire department and sprinkler connections, sprinkler head clearance, and the annual inspection of fire protection and ventilation systems. Power system and electrical safety covers damaged, frayed, or improperly installed wiring and cables, and the specific locations where hazards are found. Where a measurement is required, record it in millimetres: the minimum clear width of the primary escape route, and the clearance below the nearest sprinkler head, which should not fall below 500 mm. Where a judgement is required, the checklist uses ratings on a 0 to 10 scale, with 0 representing a critical hazard or non-compliant condition and 10 representing full compliance. An overall priority level is also assigned to the issues identified.
Why this matters
A fire safety inspection is a proactive exercise. Its purpose is to strengthen fire safety awareness, identify potential fire hazards, and ensure timely corrective actions rather than to react after an incident. By checking the systems that protect occupants and the routes they would use to leave, you confirm that building owners and occupants are adhering to established fire protection procedures and protocols. Documenting findings with photographs and notes matters as much as the walkthrough itself. A clear record lets you track recurring issues, evaluate overall facility safety, and demonstrate compliance with fire safety regulations.
How to carry out the inspection
Work through the building systematically, using your own senses and a few basic tools: a tape measure for the escape route width and sprinkler head clearance, and a camera for photographic evidence of equipment defects that could contribute to fires or explosions. 1. Begin with smoke protection doors. Open and close each one, checking that it self-closes, that hinges are sound, that glazing is intact, and that no door is wedged open. 2. Walk the escape routes as an occupant would. Look for anything blocking the way: rubbish, discarded furniture, unauthorised cabinets, shelving, or storage. Check for unauthorised wall penetrations in stairwells. 3. Test the doors along those routes. None should require a key to open from the inside, and the main roof access door should not be secured with a lock requiring a key from within. 4. Confirm that emergency lighting and exit signs are working and legible. 5. Measure the minimum clear width of the primary escape route and record it in millimetres. 6. Inspect every item of fire equipment. Check extinguishers, manual alarm call points, hydrants, and hose reels for damage, obstruction, and maintenance status. Check the signage for fire department connections, sprinkler connections, hose reel cabinets, and hose reel storage. 7. Check sprinkler heads. They should be free from obstruction by shelving, merchandise, or fixed structures, with at least 500 mm of clearance below each head. Measure and record the clearance below the nearest head. 8. Confirm that fire department inlet connections are not blocked by swing gates, furniture, or other objects, and that fire department elevator signage is legible and present. 9. Ask whether fire protection systems and the ventilation system are maintained and inspected annually by registered fire equipment service companies and registered ventilation contractors respectively. 10. Inspect electrical wiring and cables for damage, fraying, or improper installation, and note the specific location of each hazard you find. 11. Record your overall ratings for electrical safety and fire safety compliance, and set the priority level for the issues identified. 12. Close with a summary of key findings, identified risks, and recommended corrective actions, then sign and complete the inspection.
Frequently Asked Questions
Ready to simplify inspections and get your team moving faster?
Start free today and turn inspections into a clear, consistent digital workflow. Prefer a guided walkthrough? Book a demo and see how flowdit can fit your team.