Fire Safety Inspection Form
This comprehensive fire safety inspection checklist facilitates routine fire safety assessments and helps verify whether fire safety procedures and protocols are properly followed by building owners and occupants. It serves to raise fire safety awareness and proactively identify potential fire hazards. Use this checklist to capture photographic evidence of any equipment defects that could lead to fire or explosion, document all observations in detail, and track recurring issues to continuously evaluate facility safety and regulatory compliance with fire safety regulations.
Use this template with flowdit
- Customize this template or build your own
- Complete inspections using the mobile app
- Get reports and analyze your data
Start inspecting smarter — free for one user.
How to Use This Checklist
- Walk the site section by section and set each answer to Yes, No, or N/A according to whether the condition described is present. Record anything that needs context in the field notes.
- Photograph every defect you find, particularly equipment defects that could lead to fire or explosion, so the record is unambiguous.
- Complete the inspection summary with the overall fire safety compliance rating, the total number of deficiencies identified, additional observations and recommendations, and your signature.
- Use the recurring issues you have logged to evaluate the facility's safety over time and to plan follow-up work.
Start inspecting smarter — free for one user.
What a Fire Safety Inspection Covers
A fire safety inspection checks the building for the conditions that let a fire start, spread, or trap occupants: defective smoke and fire doors, obstructed escape routes and emergency exits, lapses in firefighting facilities, and unsafe electrical wiring. The inspection below prepares you to assess the building's protection in six sections: - **Smoke Door Management** — whether smoke and fire doors are missing, defective, or have damaged hinges or broken glass, are left open, or have unit entry gates that open toward escape routes. - **Escape Routes and Emergency Exits** — obstructions along escape routes, locking devices that cannot be opened from the inside without a key, unauthorized openings and structures, emergency lighting, and exit signage. - **Firefighting Facilities Maintenance** — extinguishers, manual fire alarm call points, hydrant and hose reel systems, fire service entrance and equipment signage, sprinkler heads, and any tampering with the installations. - **Electrical System Maintenance** — damaged, frayed, or improperly arranged wires. - **Inspection Summary** — your overall fire safety compliance rating, the total number of deficiencies identified, additional observations and recommendations, and a signature.
Why Fire Safety Inspections Matter
Buildings need routine inspection because fire protection fails quietly. A smoke door propped open, a locking device fitted along an escape route, or an extinguisher that has never been maintained will not show up until the moment it is needed. Routine inspection is how you find these conditions while they can still be corrected. It raises awareness among building owners and occupants, and it produces a record of what you observed, what equipment was defective, and what still needs attention. That record supports continuous evaluation of the facility's safety and compliance with the fire safety regulations that apply to it.
Smoke Door Management
Smoke and fire doors are the building's first line of compartmentation, so each inspection begins with them. Walk every unit and common area door and check for: - Doors that are absent, defective, or have damaged hinges or broken glass. - Doors that have been left open or are not properly closed. - Unit entry gates that open toward escape routes and obstruct them. - Locking devices that cannot be opened from the inside without a key, including on the main rooftop door. Any door that cannot be closed or is secured against the people who need to pass through it is a finding, not an inconvenience.
Escape Routes and Emergency Exits
An escape route only works if it is clear, lit, and unobstructed from end to end. Follow the route from the furthest point to the final exit and look for: - Unauthorized openings in stairwell walls, such as for exhaust fans, air conditioning units, doors, or windows. - Unauthorized structures such as cabinets, shelving, or storage units placed along the route. - Discarded furniture, debris, or similar obstructions. - Emergency lighting that is damaged or non-functional. - Exit signs that are damaged, illegible, or not illuminated. Record the location of every obstruction so it can be cleared and the reason it appeared can be addressed.
Firefighting Facilities Maintenance
The equipment that fights a fire has to be present, serviceable, visible, and reachable. Check each item on the list, including: - Fire extinguishers that are defective, damaged, missing, or lacking proper maintenance. - Manual fire alarm call points that are defective, damaged, or obstructed. - Hydrant and hose reel systems that are defective, damaged, or obstructed. - Fire service entrance signs, extinguisher signs, hose reel signs, and cabinet labels that are missing. - Obstructions at the building's fire service access points, such as movable metal gates or light fixtures. - Sprinkler heads blocked by storage shelving, merchandise, or fixed structures such as attics and cabinets. - Evidence of tampering with fire service installations, such as shutting off sprinkler control valves. - Fire elevator signage that is illegible or missing. Two of the items concern maintenance arrangements rather than the equipment itself: whether the fire service installations are being annually inspected by a registered fire service installation contractor, and whether the ventilation system is annually inspected by a registered specialist ventilation contractor. If you cannot confirm that either inspection has taken place, treat it as a finding and ask for the record.
Inspection Summary
Close the inspection by recording the overall fire safety compliance rating, the total number of deficiencies you identified, and any additional observations and recommendations. Sign the summary and note the start and end dates of the inspection. The summary is what turns a set of observations into a plan. Review the deficiencies you have recorded, note any that recur from previous inspections, and set out what needs to be corrected and what should be re-checked.
Frequently Asked Questions